MET ONE 3411 Portable Wireless

2088800-02


Part of the MET ONE Facility Monitoring System. MET ONE 3411 Portable Air Particle Counter (0.10 μm / 1.0 CFM)
 

Especificaciones

Platform APC Instruments
Performance ISO 21501-4 unit-to-unit accuracy & reproducibility
Industry Standards ISO 21501-4 , 21 CFR Part 11, ISO 14644-1:2015, FCC, CE
Light Source Helium neon laser
Particle Size Analysis Range 0.1 - 5 μm / 0.1 - 5 μm
Coincidence Loss % at 1,765,000 particles/m3 (per ISO 21501-4 method)
Sample Volume 5 µm
Throughput 28.32 L per minute
Interfaces & Protocols RS232, RS485, 802.11 b/g Wireless, 802.3 Ethernet, USB Client (v1.1) & USB Host (v1.1) interfaces, Modbus TCP, Modbus RTU, Serial FX
Data Storage 5000 samples
Reporting EU GMP (2015), ISO 146441-1.2015, FS209E, BS5295, ISO 14644-1:1999
Battery Lithium ion smart battery (rechargeable, ejectable & hot-swappable)
Battery Operating Time 3 hours (minimum)
Battery Recharge Time 6.75 hours (minimum) - 10 hours (maximum)
Pump Type Air vacuum, rated for continuous use
Zero Count ISO 21501-4 & JIS B 9921 (1 count or less in 5 minutes; 95% Upper Confidence Limit)
Counting Efficiency 50% at 0.1 μm (100% for particles > 0.15 μm per ISO 21501-4 & JIS B 9921)
Count Alarms, Display & Cycles User-defined alarm counts, Raw counts: N/CF, N/CM, N/L in cumulative or differential mode
Label Locations ID: 0 to 999; NAME: Alphanumeric (appears on printout)
Environmental Conditions Indoor Environment
Temperature Range Storage temperature range: -40°C to 50°C, Operating temperature range: 0°C to 40°C
Humidity Restrictions 10%-90% relative humidity (non-condensing)
Power Requirements 24 VDC, 3.2 A with 100-240 VAC, 50/60 Hz adapter (included in ship kit)
Operating System Windows® CE
Software Simply Paperless Secure PDF Option
Resolution 320 x 240
Display Color 1/4 VGA TFT touch screen
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 15.9 kg (without battery)
Width 33 cm / 13 in
Depth 56 cm / 22 in
Height 23 cm / 9.1 in
Color Silver
Package Quantity 1

Customers Also Viewed

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.