Avanti® J-26S XPI BioSafe Non-IVD Centrifuge, 50 Hz, 230V

B22989


High speed, low heat output, imbalance tolerance and low noise for standard-setting performance. The J-26S XPI’s vast range of separations only continues to grow. The addition of the HEPA (high-efficiency particulate arrestance) filter kit in this build makes the instrument BioSafe. The J-26S XPI Centrifuge has a more impact-resistant lid, full containment barrier and automatic rotor identification. Its ergonomic design--with lower instrument height and hands-free door operation--remains unchanged. The J-265 XPI can process six liters of fermentor output in less than 10 minutes, deliver a subcellular fraction at 82,000 x g and run 24 microplates at a time. It automatically detects which rotor is installed and prevents the rotor from running above its maximum-rated speed, and enables quicker, quieter, more energy-efficient runs with better temperature control. The exclusive high-torque, switched reluctance (SR) drive shortens cycle times.

Especificaciones

Platform Avanti
Maximum Speed 26,000 rpm
Maximum g-Force ||82,000.00|x g
BioSafe Yes
Acceleration Maximum, Slow or Timed (1-10 minutes, 0-500 rpm)
Deceleration Maximum, Slow, Timed (1-10 minutes from 500-0 rpm) or Off
Speed Control ± 10 rpm of set speed or 0.1%, whichever is greater
Timed Run 1 min to 99 hr 59min, W2t or Continuous hold
Max Capacity Volume Range 1 - 6 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Temperature Range(s) 10°C - 40°C in 1 degree increments
Rotor ID Automatic
Zonal Capability Yes
Pollution Degree 2
Environmental Conditions -10°C to 40°C in 1° increments
Installation Category II
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Material(s) Steel, Plastic
Finish Powder Coat Paint
Weight 290 kg / 639.3 lb
Width 71 cm / 28 in
Depth 86.0, 102.0 with air direviter extending cm / 86.0, 102.0 with air direviter extending in
Height 86 cm (149 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Humidity Restrictions < 95% (non-condensing)
Power Requirements 230 VAC, 50 Hz
Customers Also Viewed

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.