HIAC 8011+ HRLD-100, MTD

8011+053


The HIAC™ 8011+ Liquid Particle Counting System, is the culmination of over 30 years of particle counting expertise. Designed for ease of use, one button sampling yields results in under 60 seconds. The sample management system ensures consistent, accurate data and is capable of testing fluids from 1cSt to 425cSt without dilution. HIAC - the benchmark in industrial liquid particle counting, the brand you know and trust.

Especificaciones

Platform LPC Instruments
Performance ± 2.5% flow accuracy
Industry Standards ASTM D7619-12, Counts / mL, DEFSTAN 91-91, GOST 17216-2001, ISO 4406, NAS 1638, NAVAIR 01-1A-17, Raw Counts, SAE AS 4059
Light Source Light obscuration
Calibration Intervals and Options 6 month calibration: ISO-MTD
Particle Size Analysis Range 4 - 70 μm / 4 - 70 μm
Coincidence Loss 10%
Sample Volume 5-100 mL
Fluid Compatibility Akso Fyrquel™, Alcohols, Aldehydes, Aromatics, Diesel fuel, Esters, Ethers, Fuels, Jet fuel (JP4, JP5, & others), Kerosene, Ketones, MIL-H-5606, MIL-H-83282, Marston Bentley HW 540, Mineral oil, Mobile Zerol™ 150, Monsanto Coolanol™, Monsanto Skydrol™, Shell Tellis™, Stoddard Solvent
Concentration Range 0 to 10000 particles/mL
Operating Range to 90 psig maximum
Tare Volumes 0.1 to 100 mL
Data Storage 3,000 records
Reporting External printer, PDF, TSV
Pump Type Fluid degas vacuum (optional pump necessary)
Environmental Conditions Maximum altitude: 2000 m, Safe for indoor use only
Installation Category II
Temperature Range Operating temp range: 5°C to 40°C, Storage temperature range: -35 to +65°C 
Humidity Restrictions 10%-80% relative humidity (non-condensing)
Power Requirements 100-230 VAC, 50/60 Hz, Optional pump: 100 VAC, 115 VAC, 50/60 Hz, 4.4 A maximum, With external air compressor: 5.2 A maximum
Display 7" LCD
Operating Modes Bottle
Pollution Degree 2
Weight 26.4 kg / 58.2 lb
Width 38.2 cm / 15 in
Depth 40.8 cm / 16.1 in
Height 71.7 cm / 28.2 in
Color Gray
Package Quantity 1

Customers Also Viewed

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.