USP <788>, <787> and EP2.9.19
Defining allowable limits of sub-visible particulates in parenteral formulations
Chapters <788> and <787> of the United States Pharmacopeia (USP), Particulate Matter in Injections, and chapter 2.9.19 of the European Pharmacopoeia apply to most small- and large-volume parenteral products, particularly ready-to-use solutions for intramuscular, subcutaneous or intravenous (IV) injection.
USP defines particulate matter as mobile undissolved particles, other than gas bubbles, unintentionally present in the solutions. Further, it provides 2 tests for detecting subvisible particulates—light obscuration technology and microscopic assay. USP<788>, <787> and EP2.9.19 are harmonized and state a preference for using the light obscuration counter, deferring only to the microscopic method when the light obscuration instrument cannot be used for some reason. These instruments are generally accepted for use in testing:
- Small-volume parenteral infusions/injectables (ampules and vials)
- Large-volume parenteral infusions/injectables (IV solutions)
Although light obscuration technology is generally the preferred testing method, it may be necessary to test some formulations using light obscuration and a microscopic particle count test to confirm compliance with applicable requirements.
Note that USP <788> does not apply for:
- Radiopharmaceutical preparations
- Parenterals for use only as irrigating solutions
- Parenterals requiring use of a filter prior to administration (provided scientific data justifies an exemption)
Helpful Links
-
Industry Standards
- USP<643>
-
21 CFR Part 11 - Data Integrity
- Productos relacionados con la 21 CFR Parte 11: Instrumentos Beckman para el cumplimiento y la integridad de los datos
- 21 CFR Part 11: Scope and Application
- Centrifugation That Supports 21 CFR Part 11 Compliance
- Equivalentes globales y normativas relacionadas
- Mejore la integridad de sus registros electrónicos
- 21 CFR Part 11 - Terms and Acronyms
- Maintaining Data Integrity: Understanding FDA ALCOA Guidance
- EP 2.2.44
- EU GMP Annex 1
- EU GMP Annex 11
- ICH Q2
- ISO 21501
- ISO Regulations
-
Reglamento IVD (IVDR)
- IVDR compliant instruments*
- IVDR compliant software*
- IVDR compliant reagents
- E-book
- Future proofing your flow cytometry panel under IVDR
- Panel IVD FCM desarrollado en laboratorio o no: depende
- Building IVDR compliant panels for haematological disorders
- Seminario web sobre el impacto de la nueva normativa de la UE sobre DIV en el día a día del laboratorio clínico de citometría de flujo
- Pruebas desarrolladas en laboratorio (LDT) frente al flujo de trabajo de validación IVD
- Conozca al experto — Doctor Maurizio Suppo
- Posibles implicaciones del Reglamento IVD de la UE en los laboratorios clínicos de citometría de flujo
- Annex I Global Safety and Performances Requirements
- IVD-R: principales consideraciones para validar un ensayo de citometría de flujo según los requisitos de la ISO 15189
- Regulatory Entities: Separation with Cooperation
- USP 1046
- USP 1047
- USP <788>, <787> and EP2.9.19
- USP <790>
- Norma ISO 11171
-
ISO 14644: Limpieza de partículas en el aire en salas limpias y zonas limpias
- Contadores de partículas diseñados para cumplir los requisitos de las normas ISO 14644-1 e ISO 21501-4
- Normas publicadas en 2015 para la ISO 14644
- Clasificación de la limpieza del aire por concentración de partículas de la ISO 14644-1
- ISO 21501-4: Contador de partículas en el aire por dispersión de luz para espacios limpios
- Recuento de partículas: Términos y fórmulas
-
USP <787>
- USP <787>: Soluciones de análisis de partículas para control de la contaminación
- Oscurecimiento de la luz: Método óptico para la detección de partículas
- USP <787>: Materia particulada subvisible en inyecciones terapéuticas de proteínas
- USP <787>: Aplicación y alcance
- Requisitos de la sala limpia para las pruebas de partículas en líquido